RBQ licensed & insured Written warranty Free estimate within 24h
Groupe GZ Groupe GZExcavation & drainage

Service 03

Spray foam
insulation

Insulation, air barrier and vapour barrier in one application. Spray polyurethane foam conforms to every irregularity in the concrete and seals air leaks where mineral wool and rigid board let them through.

On video

The application,
filmed on our job sites

Left: spray foam in a crawl space. Right: sealing a foundation wall and rim joist. The foam is projected in thin, controlled passes — that’s what guarantees uniform thickness and adhesion.

  • Closed-cell foam, roughly R-6 per inch, built-in air and vapour barrier.
  • Thickness gauge-checked on every pass, never eyeballed.
  • Site masked and ventilated before, during and after application.
Crawl space
Wall & rim joist

Three jobs in one pass

In a basement, performance doesn’t come down to R-value alone. Insulation with air circulating behind it loses much of its effectiveness, and warm air touching cold concrete produces condensation — which means mould. Closed-cell spray polyurethane foam solves all three problems at once:

  • Insulation — roughly R-6 per inch, the best value per inch among common insulations.
  • Air barrier — it bonds to the substrate and seals joints, corners and penetrations.
  • Vapour barrier — at the required thickness it blocks vapour migration with no additional vapour barrier.

Where we apply it

  • Basement walls. Directly on the concrete, before framing. No air gap, no thermal bridging at the studs.
  • Slab and foundation wall. On the concrete slab before finishing, and around the foundation wall to cut the thermal bridge at the slab-wall junction.
  • Crawl spaces. Walls, floor and rim joists. Often the main source of humidity in a whole house.
  • Rim joists. The number one air leakage point in a Quebec home.
  • Garages and cantilevers. Garage ceilings under living space, overhanging sections.
  • Cathedral ceilings and attics. Where ventilation space is limited.
Two-pound or half-pound?

In basements and in contact with concrete, we use closed-cell foam (“two-pound”). It resists water and acts as a vapour barrier. Open-cell foam (“half-pound”) is vapour-permeable: it has its place elsewhere in the building, not against a foundation.

Our procedure

  1. Inspection and measurement. We verify the condition of the concrete, look for active infiltration and check moisture levels. We never spray foam over an unresolved water problem.
  2. Preparation. Surfaces cleaned, windows, floors and equipment masked. Job-site ventilation set up.
  3. Application. Sprayed in successive passes to the specified thickness, verified with a depth gauge. The space stays unoccupied during application and the re-entry period.
  4. Trimming and finishing. Excess shaved flush with the framing, full cleanup and removal of offcuts.
  5. Thermal barrier. A Code reminder: exposed foam must be covered with a thermal barrier — usually drywall — in occupied spaces.

Grants and payback

Basement insulation work qualifies for several provincial and federal grant programs, including Renoclimat, which requires an energy assessment before and after the work. We explain the process and supply the technical documentation your advisor needs.

In practice, most owners notice a basement that stops being cold and damp, a more comfortable main floor, and a clear reduction in winter drafts.

Frequently asked

Do we have to leave the house during application?
The work area must be unoccupied during application and for the manufacturer’s recommended re-entry period (generally 24 hours). Depending on the layout of the house and how well the work area is isolated, leaving the home isn’t always necessary — we confirm before the job.
Does the smell last long?
There is an odour during application and for a few hours afterward. With proper job-site ventilation it normally clears within one to three days. Correctly metered, correctly applied foam gives off nothing once cured.
Can it go on a wall that has leaked before?
Only after the source has been dealt with. Insulating over an active leak traps water behind the foam and hides the problem. That’s why we always look at the drain and any cracks before spraying.
What thickness do I need?
It depends on the target R-value and the vapour barrier role. In basements we aim for a thickness that meets both the Code insulation requirement and the required permeance. We calculate it and write it into the quote.

On site

Recent applications

Next step

A basement you
actually want to use

Insulation, air sealing and moisture control, done together and in the right order.

Call us Get a quote